Install Wire Strap

STEP 3.5

Measure the edge of the Heated Area where
Wire Strap will be installed.

Double-sided tape

STEP 3.6

Cut the Wire Strap to length using metal
shears.

STEP 3.7

Secure the strap to the floor. Depending on
the floor type, different methods may be used.

Concrete, self-level, or similar:

Double-sided

tape (if included with your cable), hot glue, or
strong spray adhesive may be used if the floor
is well cleaned and the strap is wiped free of
any oils. However, it is highly recommended
to also place screws at each end of the strap,
and every 4 to 5 feet, to ensure it does not
come loose. If using a strong spray adhesive,
apply to both the back of the strap and the
floor where it will be placed, and carefully
follow all spray manufacturer’s instructions
and cautions.

STEP 3.8

Cut another piece of strap for the other end
of the area and secure to the floor.

Hot glue

Spray adhesive

OR

OR

OR

Plywood, cement board, or similar:

Galvanized

nails or screws may be used to secure the
strap every 6" to 10".

Galvanized nails

Screws