Ivoclar Vivadent EP 600 User Manual

Page 15

Advertising
background image

15

The furnace components are
assembled as follows:

Step 1:

Assembling the tray and the
firing plate

– Mount the supports for the

sagger tray (25)

– The sagger tray (1) is slipped

onto the screws (2). If
desired, the screws may be
tightened using a screwdriver.

– Remove the firing plate (50)

from the protective paper
and place it in the stone
lining.

– Clean the sealing surface (19).

Step 2:

Assembling the furnace head
The furnace head is best
assembled with the rear of the
furnace base placed as shown in
the corresponding figure. Lift
the furnace head with both
hands and slip the plug-on
console (77) onto the correspon-
ding pegs (75) in the furnace
base until the leaf spring (76)
audibly snaps into place.

Please make sure that
no cable is caught
between the furnace
head and the furnace
base and that the red
marks are lined up.

Step 3:

Mounting the connections

– Connect the cables of the

furnace head with the
furnace base.

– Insert the heater plug (66)

into the heater socket (17)
and secure it with the
retention screw (67) with a
right-hand turn.

– Insert the thermocouple plug

(64) into the thermocouple
socket (18).

– Make sure the polarity of the

plug is correct (+ signs
together).

– Insert the press drive plug

(65) into the press drive
sockets (16) until it audibly
snaps into place.

– Mount the grounding band

(78) of the furnace head
onto the sip-on tongue of
the furnace base (23).

2

77

75

76

66

64

18

65

16

23

78

67

17

1

25

1

Advertising