Operation and standard settings – Ivoclar Vivadent EP 600 User Manual

Page 18

Advertising
background image

18

5.1 Starting the furnace

5.1.1 Start-up
After the furnace has been switched on, the
unit undergoes a self-test, and if necessary, a
preheating cycle. The furnace selection
menu is shown on the display.

To reduce the moisture in the

press chamber (stone lining) the
vacuum pump is switched on

during the pre-heating phase, thus removing
the moist air.

As of Software Version V3.0 the vacuum
pump is kept on during the complete pre-
heating phase.

5.2 Introduction to the

operation "Pressing"

The EP 600 is designed for use with Ivoclar
Vivadent all-ceramic systems (IPS e.max,
IPS Empress). Therefore, the corresponding
parameters of the various programs have
already been set in the factory. All you have
to do is select the desired program for the
corresponding material using the function
keys F1 (104), F2 (105), F3 (106), or F4
(107). Next select whether you are using a
large or small investment ring.
After that, the display indicates the
corresponding program cycle diagram. The
program is started by pressing START.
The firing of the press cycle selected is
graphically displayed. The most important
parameters are visible on the display (74) at
all times.

5.2.1 Main menu "Pressing"

Page 1

Page 2

Page 3

Page 4

Now the press program is selected using the
function keys. This menu always displays
three programs, which may be selected by
means of the function keys F1, F2, and F3.
The menu comprises several pages. F4 is
used to move forward.
On the last Page there is a menu
”miscellaneous”

5.2.2 Menu "Investment ring selection"
This menu is used to indicate which
investment ring (large, small) will be used.

5.2.3 Menu "Program"

In this menu, a graphical representation of
the currently selected program is displayed.
The temperature curve indicates the set
temperature values. The progress of the
running program is shown by a bold line.
The remaining time until the start of the
actual press process is also indicated. As
soon as the press process has commenced,
the time passed since the beginning of the
press process is indicated.

Furthermore, the display indicates the
distance travelled by the press plunger in the
selected unit of measure since the beginning
of the press process, as well as the quality of
the vacuum in percent. If no program is in
progress, F2 and F3 can be used to change
between the various programs.

With F4, the parameters of the currently
selected program can be viewed (see menu
"Program parameters").

5.2.4 Menu "Program parameters"

In this menu, the set parameters of the
selected program are displayed or edited
(for freely programmable programs).

Pressing F1 returns you to the menu
"Program".

5. Operation and Standard Settings

Advertising