3. Product Description

3.1 Components

The Programat S1 consists of the following components:
– Furnace base with electronic controls
– Furnace head with sintering chamber
– Sinter tray
– Cooling plate
– Sinter tray fork
– Cleaning brush

3.2 Hazardous areas and safety equipment

Description of the hazardous areas of the furnace:

Hazardous area

Type of risk

Sintering chamber

Risk of burning

Opening and closing
mechanism

Risk of crushing

Electrical components

Risk of electrical shock

Description of the safety equipment of the furnace:

Safety equipment

Protective effect

Protective conductor

Protection from electrical shock

Electrical fuses

Protection from electrical shock

Furnace housing and covering
ends

Protection from electrical shock,
burning and crushing

3.3 Functional description

The sintering chamber may be heated up to max. 1530 °C (2786 °F)
by means of a heating element. The sintering process is controlled
with the corresponding electronic controls and software. Moreover,
the set and actual temperatures are continuously compared.

3.4 Accessories

– Temperature Checking Set S1

3.5 Indication / contraindication

Indication
– Sintering of ZrO

2

materials

Contraindication
– The Programat S1 is not suitable as a ceramic furnace for dental

laboratories.