8.2 Technical malfunctions

These malfunctions may occur without an error message being displayed:

Error

Double Check

Measure

Display indication incomplete

Activate the display test program and contact the
Ivoclar Vivadent After Sales Service.

Writing in the display is very hard to read

Is the contrast properly set?

Adjust contrast

Display is not illuminated

Is the furnace properly connected according to the
Operation Instructions and switched on?

Correctly connect the furnace and switch it on.

Buzzer does not sound

Is the buzzer switched off (Tune 0)?

Select tune 1–5

Furnace head does not open

Was the furnace head opened manually?

Open the furnace head only by using the corres-
ponding keys. Switch the furnace on and off again.

Incorrect or illogical temperature indication

Is the thermocouple bent or fractured?

Contact the Ivoclar Vivadent After Sales Service

Is the thermocouple correctly connected?

Correctly connect the thermocouple

Is the thermocouple plug defective?

Contact the Ivoclar Vivadent After Sales Service

Cracks in the insulation of the sintering chamber

Are the cracks very small and insignificant (hairline
cracks)?

Small cracks in the insulation do not negatively
influence the furnace.

Are the cracks large or have parts of the sintering
chamber broken off?

Contact the Ivoclar Vivadent After Sales Service

Cracks in the insulation

Are the cracks very small and insignificant (hairline
cracks)?

Small cracks in the insulation do not negatively
influence the furnace.

Are the cracks large or have parts broken off?

Contact the Ivoclar Vivadent After Sales Service

Damage of a heating element

Is a heating element bent or fractured?

Switch off the furnace and contact the Ivoclar
Vivadent After Sales Service

Damage of the thermocouple

Is the thermocouple damaged or broken off?

Contact the Ivoclar Vivadent After Sales Service

8.3 Repair

Repairs may only be carried out by a certified Ivoclar Vivadent After Sales Service Centre.

Please refer to the addresses in Chapter 10.

If repairs during the warranty period are not carried out by a certified Ivoclar Vivadent After Sales Service
Center, the warranty will expire immediately. Please also refer to the corresponding warranty regulations.

Advertising
This manual is related to the following products: