Product specifications – Ivoclar Vivadent S1 User Manual

Page 30

Advertising
background image

9. Product Specifications

9.1 Delivery form

– Programat S1
– Power cord
– Temperature Checking Set S1 Starter Kit
– Operating Instructions
– Sinter tray
– Sinter tray fork
– USB download cable
– Equipment Service Passport
– Various accessories

9.2 Technical data

Power supply

118–240 V / 50–60 Hz




Overvoltage category II
Contamination level 2

Acceptable voltage fluctuations

+/- 10%

Max. power consumption

16 A at 118 V

8 A at 240 V

Electrical fuses

250 V / T16 A high breaking (heating circuit)

Dimensions electrical fuses

Diameter 5 x 20 mm

Dimensions of the closed furnace

Depth: 430 mm / Width: 310 mm / 390 mm (with cooling tray)

Height: 570 mm

Usable size of the sintering chamber

Diameter 80 mm

Height 80 mm

Max. firing temperature

1530 °C/2786 °F

Weight

Furnace base: 10 kg

Furnace head: 17 kg

Safety information
The sinter furnace complies with the following guidelines:
– IEC 61010-1:2001
– EN 61010-1:2001
– UL 61010-1:2004
– CAN/CSA-C22.2 No. 61010-1:2004
– IEC 61010-2-010:2003
– EN 61010-2-010:2003
– CAN/CSA-C22.2 No. 61010-2-010:2004

Radio protections / electromagnetic compatibility

EMV tested

9.3 Acceptable operating conditions

Acceptable ambient temperature range:

+5°C to +40°C (+41°F to +104°F)

Acceptable humidity range:

80 % maximum relative humidity for temperatures up to 31°C

(87.8° F) gradually decreasing to 50 % relative humidity

at 40°C (104°F); condensation excluded.

Acceptable ambient pressure:

The furnace is tested for use at altitudes of

up to 2000 m above sea level.

9.4 Acceptable transportation and storage conditions

Acceptable temperature range

-20 to +65°C (-4°F to +149°F)

Acceptable humidity range

Max. 80% relative humidity

Acceptable ambient pressure

500 mbar to 1060 mbar

Use only original packaging of the Programat S1 together with the
respective foam material for shipping purposes.

30