saliva), repeat the etching procedure with a reaction time
of max. 10 seconds.
The reaction time on unprepared enamel (e.g. fissure
sealants) is 30–60 seconds. If the enamel is selectively
etched, use a reaction time of 15–30 seconds.

Refilling empty Total Etch syringes

Empty 2-gram syringes can be
conveniently refilled with the
contents of the Total Etch
Jumbo syringe up to 15 times.

Important
Although the 2-gram syringes are equipped with a plunger
safety stop, it is absolutely necessary to wear gloves,
protective goggles and a face mask for safety reasons.
– Remove the screw-on cap from the 30-gram Jumbo

syringe and the empty 2-gram syringe.

– Join the tips of the two syringes using a twisting, clock-

wise motion. Make sure that the two syringes are firmly
connected. Note: Do not strip the thread.

– Refill the small syringe by slowly and steadily pulling

back the plunger of the small syringe. Simultaneously
exert light pressure on the plunger of the jumbo syringe
using the other hand to support the refilling process.

– Avoid overfilling the small syringe.
– Under no circumstances should you exceed the

plunger safety stop of the small syringe due to the
risk of acid burn!

– Do not point the syringes at people during refilling.
– Do not fill etchant from the 2-gram syringe back into the

Jumbo syringe.

– Disconnect the two syringes using a counter-clockwise

twist.

– Replace the screw-on cap on the Jumbo syringe.
– The syringe is now ready for use. Attach an application

tip onto the 2-gram syringe. Apply the etchant as descri-
bed above.

– Use only the Total Etch application tips delivered with

this package. The use of other application tips may have
an adverse effect on the viscosity of the etchant.

– In order to ensure traceability, only the enclosed 2-gram

syringes should be refilled with the contents of the
Jumbo syringe delivered with the same package.

– Please indicate the LOT number on the Jumbo syringe in

case of any query.

Warning

When filling the 2-gram syringe, always wear

protective goggles and gloves.
Total Etch contains phosphoric acid and is
corrosive. Avoid contact with the eyes, mucous

membrane, and skin (goggles are recommended for both
patients and operators). After contact with the eyes, imme-
diately rinse with copious amounts of water for at least 15
minutes and see a physician/opthalmologist.
After skin contact, immediately rinse with soap and water.
After contact with sensitive materials (sur faces, clothing),
immediately clean with copious amounts of water.

Storage
– Do not use Total Etch after the date of expiration.
– Storage temperature: 2–28 °C (36–82 °F). Recommen -

dation: Refrigerate large inventory at 2–8 °C (36–46 °F).

– Date of expiration: see note on syringe/packaging.

Keep out of the reach of children.
For use in dentistry only.

This material has been developed solely for use in dentistry.
Processing should be carried out strictly according to the Instructions for Use.
Liability cannot be accepted for damages resulting from failure to observe the
Instructions or the stipulated area of application. The user is responsible for testing
the material for its suitability and use for any purpose not explicitly stated in the
Instructions. Descriptions and data constitute no warranty of attributes and are not
binding.