Ò³ãæ 30, Measuring range and bearing between two targets – Onwa Marine Electronics KR-1338C v.1 User Manual

Page 30

Advertising
background image

Measuring range and bearing between two targets

The procedure which follows shows how to measure the range and bearing betw-
een target

's origin (cursor) on the center of target

's

origin shifts to cursor.
4. Press the [EBL/VRM CONTROL] key.
5. Press the onmipad to bisect target

"A" and target "B" in Figure 2-11.

1. Press the omnipad to place EBL1

"A".

2. Press the [EBL/VRM SELECT] key to choose EBL1 readout and then press the
[EBL/VRM CONTROL] key.
3. Select EBL OFFSET on the menu and press the [ACQ/ENTER] key. EBL1

"B" with EBL1. Check the EBL1 readout to

find the bearing between target "A" and target "B".
6. Press the [EBL/VRM SELECT] key to choose VRM1 readout. Press the omnip-
ad to place the outside edge of VRM1 on the inside edge of target "B". Check the
VRM1 readout to find the range between target "A" and target "B".
7. To cancel, select EBL OFFSET on the menu and press the [ACQ/ENTER] key.

6.0 NM
2.0

EBL1 origin

(Initial position
of target)

Target moved

Here.

VRM1

Offset EBL
(EBL1)

VRM1
range

EBL1

bearing

70.0

R

6.0 NM

EBL

VRM1

Figure 2-10 Predicting collision course by

using the offset EBL

VRM1

EBL1

70.0

R

Bearing

VRM1

EBL1

VRM

4.5 NM

Range

Figure 2-11 Measuring the range and bearing
between two targets by using the offset EBL

22

Advertising