Figure 5-17 – OWON SDS Series User Manual

Page 41

Advertising
background image

5.Advanced User Guidebook

Figure 5-17 Video trigger menu

Video menu list:

MENU

SETTING

INSTRUCTION

Single Mode

Video

Set vertical channel trigger type as video trigger

Source

CH1
CH2
EXT

EXT/5

Select CH1 as the trigger source
Select CH2 as the trigger source
The external trigger input
1/5 of the external trigger source for increasing range
of level

Modu

NTSC

PAL

SECAM

Select video modulation

Sync

Line

Field

Odd

Even

Line NO.

Synchronic trigger in video line
Synchronic trigger in video field
Synchronic trigger in video odd filed
Synchronic trigger in video even field
Synchronic trigger in designed video line, turn the M
knob to set the line number

Mode

Holdoff

Auto

Holdoff

Reset

Acquire waveform even no trigger occurred
100ns~10s, adjust the M knob to set time interval
before another trigger occur
Set Holdoff time as 100ns

3. Slope Trigger

Slope trigger sets the oscilloscope as the positive/negative slope trigger within the
specified time.
The Slope Trigger Menu is shown as Figure 5-18.

Figure 5-18 Slope trigger menu

Slope trigger menu list:

MENU

SETTING

INSTRUCTION

Single

Mode

Slope

Set vertical channel trigger type as slope trigger.

Source

CH1
CH2

Select CH1 as the trigger source.
Select CH2 as the trigger source.

When

slope

Slope selecting

36