FIREPLACE CLEARANCES

WARNING: Maintain the

minimum clearances shown

in Figure 6. If you can, provide

greater clearances from floor,

ceiling and joining wall.

NOTICE: If you install the fire-

place in a bedroom, some

building codes require that the

fireplace/mantel system be se-

cured to (or within) a wall. You

can position fireplace in an op-

tional cabinet or corner mantel.

You can also recess fireplace

into the wall.

If your fireplace is to be used with an optional

mantel, the installation instructions included with

your mantel shows an CSA approved method of

attaching the fireplace/mantel system to a wall.

IMPORTANT:

Only use optional cabinet or

corner mantels specified in this manual. Purchase

the optional mantel from your dealer (see Acces-

sories, page 34).

If your fireplace is to be recessed into the wall,

see Built-In Fireplace Installation to secure your

fireplace into the wall.

CAUTION: If you install the

fireplace in a home garage

• fireplace pilot and burner must

be at least 18" above floor.

• locate fireplace where moving

vehicle will not hit it.

For convenience and efficiency, install fireplace

• where there is easy access for operation, inspec-

tion and service

• in coldest part of room

Minimum Clearances For Side Combustible
Material, Side Wall and Ceiling

A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 6.

Example: The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This combus-

tible material must be 4" from the side of the

fireplace opening (see Figure 6).

B. Clearances from the top of the fireplace

opening to the ceiling should not be less

than 36".

C. For mantel clearances, see Figure 10 on

page 13.

Figure 6 - Minimum Clearance for

Combustible to Wall

*Minimum 16" from Side Wall

*

Example

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top

Left and

Right Sides

Bottom and

Rear

36

"

6"

0"

bUILT-IN FIREPLACE INSTALLATION

Built-in installation of this fireplace involves install-

ing fireplace into a framed-in enclosure. This makes

the front of fireplace flush with wall. Fireplace face

will extend past sides and top of fireplace approxi-

mately 1". This will cover the rough edges of the

wall opening. If installing a built-in mantel above

the fireplace, you must follow the clearances shown

in Figure 9, page 12. To install the fireplace in this

manner, use the following instructions.