Installation – Desa CGMFP User Manual

Page 14

Advertising
background image

www.desatech.com

119315-01A

14

iNsTallaTioN

Continued

We recommend that you install a sediment trap in

supply line as shown in Figure 14. Locate sediment

trap where it is within reach for cleaning. Install

in piping system between fuel supply and heater.

Locate sediment trap where trapped matter is not

likely to freeze. A sediment trap traps moisture

and contaminants. This keeps them from going

into fireplace controls. If sediment trap is not

installed or is installed wrong, fireplace may not

run properly.

* Purchase the optional CSA design-certified

equipment shutoff valve from your dealer. See

Accessories, page 34.

Figure 14 - Gas Connection

CSA Design-
Certified Equipment
Shutoff Valve With
1/8" NPT Tap*

3" Minimum

Approved
Flexible Gas
Line

Pipe Nipple Cap Tee Joint

Propane/LP
From External
Regulator (11"
W.C.** to 14"
W.C. Pressure)

NATURAL
From Gas Meter
(5" W.C.** to
10.5" W.C.
Pressure)

Sediment Trap

CONNECTING FIREPLACE TO GAS
SUPPLY

Installation Items Needed

• Phillips screwdriver

• sealant (resistant to propane/LP gas, not

provided)

NOTICE: Most building codes

do not permit concealed gas

connections. A flexible gas

line is provided to allow acces-

sibility from the fireplace (see

Figure 1, page 5). The flexible

gas supply line connection to the

equipment shutoff valve should

be accessible.

Figure 15 - Attaching Flexible Gas Line

to Equipment Shutoff Valve

Flexible Gas Line
from Fireplace Gas
Regulator Provided
With Fireplace

To Gas Regulator
(Manual-Controlled
Models) or Control
Valve (Remote-
Ready Models)

Equipment
Shutoff Valve

PROPANE/LP
To External
Regulator

NATURAL
To Gas Supply

1. Route flexible gas line, included, from fire-

place control to equipment shutoff valve

through side or rear access holes in outer

casing (see Figure 1, page 5).

2. Apply pipe joint sealant lightly to male threads

of gas connector attached to flexible gas line/

equipment shutoff valve (see Figure 15).

CAUTION: Avoid damage to

regulator. Hold gas regulator

with wrench when connecting

it to gas piping and/or fittings

(Manual-Controlled Models

Only).

CAUTION: Avoid damage to

gas control. Hold gas control

with wrench when connecting

it to gas piping and/or fittings

(Remote-Ready Models Only).

3. Check all gas connections for leaks. See

Checking Gas Connections.

4. Feed flexible gas line into fireplace base area

while replacing branch support. Make sure the

entire flexible gas line is in fireplace base area.

Advertising