Troubleshooting – Desa CGMFP User Manual

Page 26

Advertising
background image

www.desatech.com

119315-01A

6

TRoUBlEshooTiNG

Continued

ObSERVED PRObLEM

When ignitor button is pressed,

there is spark at ODS/pilot but

no ignition

ODS/pilot lights but flame goes out

when control knob is released

Burner does not light after ODS/

pilot is lit

POSSIbLE CAUSE

1. Gas supply turned off or

equipment shutoff valve

closed

2. Control knob not in PILOT

position

3. Control knob not pressed in

while in PILOT position

4. Air in gas lines when

installed

5. Depleted gas supply (pro-

pane/LP only)

6. ODS/pilot is clogged

7. Gas regulator setting is not

correct

1. Control knob not fully

pressed in

2. Control knob not pressed in

long enough

3. Safety interlock system has

been triggered

4. Equipment shutoff valve not

fully open

5. Pilot flame not touching

thermocouple, which allows

thermocouple to cool, caus-

ing pilot flame to go out. This

problem could be caused by

one or both of the following:

A) Low gas pressure

B) Dirty or partially clogged

ODS/pilot

6. Thermocouple connection

loose at control valve

7. Thermocouple damaged

8. Control valve damaged

1. Inlet gas pressure is too low

2. Burner orifice is clogged

3. Thermopile leads disconnected

or improperly connected (Re-

mote-Ready Models Only)

4. Burners will not come on in

remote position (Remote-

Ready Models Only)

REMEDY

1. Turn on gas supply or open

equipment shutoff valve

2. Turn control knob to PILOT

position

3. Press in control knob while in

PILOT position

4. Continue holding down con-

trol knob. Repeat igniting op-

eration until air is removed

5. Contact local propane/LP gas

company

6. Clean ODS/pilot (see Cleaning

and Maintenance, page 24) or

replace ODS/pilot assembly

7. Replace gas regulator

1. Press in control knob fully

2. After ODS/pilot lights, keep con-

trol knob pressed in 30 seconds

3. Wait one minute for safety in-

terlock system to reset. Repeat

ignition operation

4. Fully open equipment shutoff

valve

5. A) Contact local natural or

propane/LP gas company

B) Clean ODS/pilot (see

Cleaning and Maintenance,

page 24) or replace ODS/pilot

assembly

6. Hand tighten until snug, then

tighten 1/4 turn more

7. Replace pilot assembly

8. Replace control valve

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner (see Cleaning

and Maintenance, page 24) or

replace burner orifice

3. Reconnect leads (see Wiring

Diagram, page 29)

4. Replace battery in hand-held

remote and receiver