ObSERVED PRObLEM

Delayed ignition of burner

Burner backfiring during com-

bustion

Slight smoke or odor during initial

operation

Fireplace produces a whistling

noise when burner is lit

White powder residue forming

within burner box or on adjacent

walls or furniture

Moisture/condensation noticed

on windows

POSSIbLE CAUSE

1. Manifold pressure is too low

2. Burner orifice is clogged

1. Burner orifice is clogged or

damaged

2. Damaged burner

3. Gas regulator defective

4. Inlet gas pressure is too low

1. Residues from manufacturing

processes and log curing

2. Not enough air

3. Gas regulator defective

1. Turning control knob to HI

position when burner is cold

2. Air in gas line

3. Air passageways on fireplace

blocked

4. Dirty or partially clogged

burner orifice

1. When heated, vapors from

furniture polish, wax, carpet

cleaners, etc. may turn into

white powder residue

1. Not enough combustion/ven-

tilation air

REMEDY

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner (see Cleaning

and Maintenance, page 24) or

replace burner orifice

1. Clean burner (see Cleaning

and Maintenance, page 24) or

replace burner orifice

2. Replace damaged burner

3. Replace gas regulator

4. Contact local natural or pro-

pane/LP gas company

1. Problem will stop after a few

hours of operation

2. Check burner for dirt and

debris. If found, clean burner

(see Cleaning and Mainte-

nance, page 24)

3. Replace gas regulator

1. Turn control knob to LO

position and let warm up for

a minute

2. Operate burner until air is

removed from line. Have gas

line checked by local natural

gas company

3. Observe minimum installa-

tion clearances (see pages 10

through 13)

4. Clean burner (see Cleaning

and Maintenance, page 24) or

replace burner orifice

1. Turn fireplace off when using

furniture polish, wax, carpet

cleaners or similar products

1. Refer to Air for Combustion

and Ventilation requirements

(page 6)