Actual Framing

Height

3

3

/

4

"



1

/

4

"

Front Width 19

3

/

4

"

1

1

/



"

Depth

8



/

8

"

8



/

8

"

Bottom

0"

0"

1. Frame in rough opening. Use dimensions shown

in Figure 7 for the rough opening. If installing in

a corner, use dimensions shown in Figure 8 for

the rough opening. The height is 22

1

/

4

" which

is the same as the wall opening above.

2. Install gas piping to fireplace location. This

installation includes an approved flexible gas

line (if allowed by local codes) after the equip-

ment shutoff valve. The flexible gas line must

be the last item installed on the gas piping.

3. If you have not assembled firebox, follow

instructions on page 6.

4. Carefully set fireplace in front of rough opening

with back of fireplace inside wall opening.

5. Attach flexible gas line to fireplace gas regula-

tor. See Connecting Fireplace to Gas Supply,

page 14.

6. Check all gas connections for leaks. See

Checking Gas Connections, page 15.

IMPORTANT:

When finishing your firebox,

combustible materials such as wall board, gypsum

board, sheet rock, drywall, plywood, etc. may be

butted up next to the sides and top edge of the fire-

box. Combustible materials should never overlap

the firebox front facing.

17

1

/

2

"

22

1

/

4

"

8

7

/

8

"

Figure 8 - Rough Opening for Installing

in Corner

Figure 7 - Rough Opening for Installing

in Wall

29

7

/

8

"

21

1

/

8

"

42

1

/

4

"

17

1

/

2

"

WARNING: Do not allow any

combustible or noncombustible

materials to overlap the firebox

front facing.

WARNING: Do not allow

noncombustible materials to

cover any necessary openings

like louvered slots.

WARNING: Never modify or

cover the louvered slots on the

front of the firebox.

Mantel Clearances for Built-In
Installation

If placing mantel above built-in fireplace, you must

meet minimum clearance between mantel shelf and

top of fireplace opening.

NOTICE: Surface temperatures

of adjacent walls and mantels

become hot during operation.

Walls and mantels above the

firebox may become hot to

the touch. If installed properly,

these temperatures meet the

requirement of the national

product standard. Follow all

minimum clearances shown in

this manual.

NOTICE: If your installation

does not meet the minimum

clearances shown in Figure 9,

page 12, you must do one of the

following:

• raise the mantel to an accept-

able height

• remove the mantel