19

OFF

PILOT

ON

opERaTiNG FiREplaCE

Continued

D. Do not use this appliance if any part has

been under water. Immediately call a

qualified service technician to inspect the

appliance and to replace any part of the

control system and any gas control which

has been under water.

LIGHTING

INSTRUCTIONS

WARNING: You must operate

this fireplace with the screen

in place. Make sure fireplace

screen is installed before run-

ning fireplace.

NOTICE: During initial opera-

tion of new fireplace, burning

logs will give off a paper-burn-

ing smell. Open window to vent

smell. Operate fireplace on HI

position to burn off odor. This

will only last a few hours.

1. STOP! Read the safety information, page 18.

2. Make sure equipment shutoff valve is

fully open.

3. Turn control knob clockwise

to the

OFF position.

4. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information, page 18. If you don’t

smell gas, go to the next step.

5. Turn control knob counterclockwise

to the PILOT position. Press in control knob

for five (5) seconds (see Figure 27).

Note: You may be running this fireplace for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds or more. This will

allow air to bleed from the gas system.

• If control knob does not pop out when

released, contact a qualified service person

or gas supplier for repairs.

6. With control knob pressed in, press and

release ignitor button (see Figure 27). This

will light pilot. The pilot is attached to

the front burner. If needed, keep pressing

ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to

Troubleshooting, page 31. Also, contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure on page 20.

7. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

Note: If pilot goes out, repeat steps 3

through 7. This fireplace has a safety inter-

lock system. Wait one (1) minute for system

to reset before lighting pilot again.

8. Turn control knob counterclockwise

to ON position. The burner should light.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Figure 27 - Control Knob In The OFF

Position

Piezo Ignitor

Control Knob

Figure 28 - Natural Gas Pilot

Thermocouple

Ignitor Electrode

Pilot Burner

Thermocouple

Ignitor
Electrode

Pilot Burner

Figure 29 - Propane/LP Gas Pilot