Troubleshooting, Cleaning and maintenance – Desa CGMFP User Manual

Page 25

Advertising
background image

www.desatech.com

119315-01A

5

LOG SET

• If you remove one-piece log set for cleaning,

refer to Installing Log Set and Screen, page 18,

for placement instructions.

• Replace log set if broken or chipped (dime-sized

or larger).

CABINET

Air Passageways

Use pressurized air to clean.
Exterior

Use a soft cloth dampened with a mild soap and

water mixture. Wipe the cabinet to remove dust.

Figure 41 - Pilot Inlet Air Hole

(Propane/LP Gas)

Pilot Assembly

Pilot Air
Inlet Hole

Pilot Assembly

Pilot Air
Inlet Hole

Figure 42 - Pilot Inlet Air Hole

(Natural Gas)

ClEaNiNG aND

MaiNTENaNCE

Continued

TRoUBlEshooTiNG

WARNING: Turn off and unplug fireplace and let cool before

servicing. Only a qualified service person should service and repair

fireplace.

CAUTION: Never use a wire, needle or similar object to clean

ODS/pilot. This can damage ODS/pilot unit.

Note:

All troubleshooting items are listed in order of operation.

POSSIbLE CAUSE

1. Ignitor electrode not con-

nected to ignitor cable

2. Ignitor cable pinched or wet

3. Broken ignitor cable

4. Bad ignitor

5. Ignitor electrode positioned

wrong

6. Ignitor electrode broken

7. Battery not installed, battery

power low or battery not

installed correctly

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched

by any metal or tubing. Keep

ignitor cable dry

3. Replace ignitor cable

4. Replace ignitor

5. Replace pilot assembly

6. Replace pilot assembly

7. Install new alkaline battery in

electronic ignitor. Verify bat-

tery is installed correctly

ObSERVED PRObLEM

When ignitor button is pressed,

there is no spark at ODS/pilot

Advertising