Delta Electronics High-Speed PCI 12-Axis Motion Control Card PCI-DMC-A01 User Manual
Page 214
Advertising

Chapter 10 Homing Motion Control Packet Protocol API | PCI-DMC-A01 / PCI-DMC-B01
10-8
Revised March, 2012
10.3 _DMC_01_escape_home_move
FORMAT
I16 PASCAL _DMC_01_escape_home_move (U16 CardNo, U16 NodeID, U16 SlotID)
Purpose
Stops homing motion.
Parameters
Name
Data Type
Unit
Description
CardNo U16
Number
Unit CardNo is between 0~15
NodeID
U16
Number Unit Node ID
SlotID
U16
Number Unit Slot ID
Example
U16 CardNo=0;
U16 NodeID=1;
U16 SlotID=0;
I16 status= _DMC_01_escape_home_move (CardNo, NodeID, SlotID);
Advertising