Maintenance & cleaning instructions 30, Maintenance & cleaning instructions – Scotsman MAR1400 User Manual

Page 30

Advertising
background image

Maintenance & Cleaning Instructions

1. GENERAL
The periods and procedure for maintenance and

cleaning are given as guides and are not to be

construed as absolute or invariable.
Cleaning especially will vary depending upon local

water conditions and the ice volume produced and

each ice maker must be maintained individually in

accordance with is own particular location

requirements.
2. ICE MAKER / CONDENSING UNIT
THE FOLLOWING MAINTENANCE MUST BE

SCHEDULED AT LEAST TWO TIMES PER YEAR

ON THIS ICE MAKER. CALL YOUR

AUTHORIZED SCOTSMAN SERVICE AGENCY.
1. Check and clean/replace water line Strainer or

Filter (when used).
2. Remove top panel and depress the float to

ensure that a full stream of water enters the

reservoir.
3. Check that the ice maker cabinet is level in

side-to-side and front-to-rear directions.
4. Check that the water level in the Drum basin is

high enough to surround the wanted portion of

revolving drum.
5. Clean the water reservoir and exterior of the

drum assembly using a solution of SCOTSMAN

Ice Machine Cleaner. Refer to procedure on the

following page, CLEANING ICE MAKER.
NOTE. Cleaning requirements vary according local

water conditions and individual user operation.
6. When doubtful about refrigeration charge, check

gauge for compressor head pressure according to

model technical specification.
7. Check gauge for Suction Line Pressure which

varies depending upon models, inlet water

temperature and ambient temperature.
8. Check drive motor operation. Normal operating

temperatures are about 60EC (160EC) which is hot

to touch. Check with ammeter for Amps drawn.
9. Check V belt for concealed signs of wear and

that has the correct tension. Check pulley

alignment and also that drive motor and gear box

hold down bolts are tight enough.
10. Make sure that water lines in water cooled

condenser are free from any excess of water

minerals: otherwise arrange to clean the tubes with

a power driven wire brush or running through it a

weak acid solution made with 20 percent of

hydrochloric acid.
11. Check for refrigerant leaks and for proper frost

line, which should frost out of accumulator at least

half way to the compressor and in some areas,

back to service valve.
Check for dryness of system through moisture

indicator if any.
12. Check for water leaks. Tighten drain line

connections. Pour water down drain to be sure that

drain line is open and clear.
13. Check the quality of ice. Ice flakes should be

dry and have a thickness gauge of about 2 m/m.
14. Check compressor oil level through sight glass.

Stop unit operation and after two/three minutes

see that oil level is 2/3 millimeters above center

line of sight glass.
15. Be sure of proper position and condition of

plexiglass chute on spout opening.