Cleaning instruction 31, Cleaning instruction – Scotsman MAR1400 User Manual

Page 31

Advertising
background image

Cleaning Instruction

1. Disconnect power front the unit.
2. Remove screws and top panel
3. Remove evaporator cover panel
4. Lock the float valve adjusting screw to avoid

water incoming during the operation of machine.
Make sure that during cleaning no ice will be

stored in any bin or cooling room in order to

avoid any kind of contamination by cleaning

solution.
5. Dump the contents from the drum basin by

withdrawing drain plug located at the bottom

refrigerant side of the evaporator. Once empty

place again plug in its seat.
Note: Plug may be covered by sealant. Remove

sealant to release plug.
6. Prepare a solution in a bucket by mixing 2 lt. (68

ounces) of Scotsman Ice Machine cleaner with 16

liter (444 oz.) of water.
WARNING: When using any chemical,

protection of hands (gloves). SCOTSMAN Ice

Machine Cleaner contains phosphoric and

Hydroxiacetic acid. These compound are

corrosive and may cause burns if swallowed.

DO NOT induce vomiting. Give large amount of

water or milk. Call Physician immediately. In

case external contact flush with water. KEEP

OUT OF THE REACH OF CHILDREN.
7. Slowly pour 90% of the solution in the

evaporator basin.
8. Connect the machine to the power and let the

unit in operation for about 10 minutes.
9. Disconnect again unit from power.
10. Repeat “5".
11. Close the water supply shut-off valve externally

connected onto the water inlet line.
12. Open a little bit the float valve holding arms

and remove it from the holder.
13. Remove screws and clip-ring securing float

valve bracket to the nozzle.
14. Withdraw bracket from float valve nozzle.
15. Place the float valve and its bracket in the

solution remained in the bucket and remove any

kind of scale or mineral deposit.

16. Carefully rinse bracket and float valve by fresh

water.
17. Prepare as per step “6" using a sanitizer rather

than a cleaner. Possible sanitizing solution may be

made by mixing 3 cl. (1 ounce) of liquid house hold

bleach with 8 liters (272 oz.) of warm potable

water.
NEVER MIX THE CLEANING WITH SANITIZING

SOLUTION.
18. Soak float valve and bracket in the sanitizing

solution for 1 minute then rinse all parts with fresh

water.
19. Install again first the plastic bracket then float

valve.
20. Open the water supply shut-off valve.
21. Leave water filling until the level inside the

basin reaches approx 8-9 cm (3-4").
22. Lock-in again float valve screw.
23. Connect the machine to the power and let the

unit in operation for about 5 minutes for rinsing the

water system.
CAUTION - DO NOT use ice produced from the

cleaning solution. Be sure none falls into

storage room.
24. Disconnect unit from power.
25. Repeat 6 then pour sanitizing solution in the

drum basin; sanitizing should last approx 5

minutes. At the end dump solution again as per

step “5". Seal plug with food grade silicon.
26. Unlock the float valve adjusting screw.
27. Replace again evaporator cover an top panel.
28. Reconnect unit to the power.

MAR1400 & MAR2000

December 2000

Page 31

Advertising
This manual is related to the following products: