Complete System Installation

How it is made
The complete scale-ice making system can be

divided in three major groups, they are:
a) the condensing unit or rack system
b) the evaporator drum unit (MAR1400 or

MAR2000) complete with drive mechanism, drive

motor, refrigerant and water lines fittings,

refrigerants expansion valve and electric wire

junction box.
c) control panel and box with compressor ON/OFF

switch, relay, timer, warning lights, pressure

switches and electrical wire terminal block,

connected to and controlling the condensing unit.

CONDENSING UNIT COMPONENTS - For

Reference Only
The condensing unit is not part of the MAR1400 or

MAR2000. They must either be connected to an

existing rack system or a separate condensing

unit.
The selection of proper type and size of

compressor together with the proper type and size

of condenser, their components and controls, is

critical for proper system operation.
The available capacity of the system must equal at

least

4800 Kcal/h at -24EC Evap. Temp. (19,000

BTUH at -11

o

F) refrigerating capacity for the

MAR1400

6500 Kcal/h at –24

o

C Evap. Temp (26,000

BTUH at –11

o

F.) refrigerating capacity for

the MAR2000

Dedicated Condensing Units: Suggested

Models
MAR1400: Use MAR1400-RHS-A/C (air cooled) or

MAR1400-RHS-W/C (water cooled)
MAR2000: Use MAR2000-RHS-A/C (air cooled) or

MAR2000-RHS-W/C (water cooled)
Condensing Unit Component Guidelines
The condenser is basically a heat exchanger

where the heat absorbed by the refrigerant during

the evaporating process is discharged to the

condensing medium, which could be air or water.
Water cooled condensers require the use of a

water regulating valve. When using a marine type

condenser a marine type water regulating valve is

required. The required capacity of the condenser is

about 30,000 BTUH for the MAR1400 and 39,000

for the MAR2000.
Particular care must be deserved to the selection

of the water cooled condenser especially the

marine type for fishing vessels installation. They

must be marine type (cupro-nickel).
The Liquid receiver is a storage tank for liquid

refrigerant. It is a common component used in

refrigeration and should be large enough to hold all

the refrigerant in the system.
A suggested component for some installations an

oil separator. When the compressor operates

small amount of oil is pumped out along with the

hot compressed vapor and to prevent it from going

any further in the system, the oil separator traps it

to return, upon opening of its float valve, to the

crankcase of the compressor.

MAR1400 & MAR2000

December 2000

Page 7

Length of Tubing Run

Suction Line

Liquid Line

4 to 15 meters (11 to 50 feet)

18 mm ID (3/4” OD)

12 mm ID (1/2” OD)

Less than 3 meters (10 feet)

14 mm ID (5/8” OD)

14 mm ID (3/8” OD)