Model 602.5SBM, Low Profile Clamshell

92-0093 Rev. 131230

After every 20 hours of actual operation

Check adjustment of the Main Bearing pre-load.

Drive torque as measured at the Drive Socket should be 5 to 10 ft-lbs. (7 to

14

N-m).

Lubricate the male and female Tool Block Slides and the Feed Screw. Refer

to the Tool Block Maintenance located later in this section.

After every 40 hours of actual operation

Thoroughly clean and lubricate Main Gear, Drive Gear, male and female Tool

Slides, Feed Screws, and Tripper Block Assy.

Non-scheduled maintenance

Readjust the Main Bearing pre-load if the Clamshell generates excessive

heat or if the Main Bearing becomes loose. Refer to the Adjustment of the

Main Bearing pre-load.

Thoroughly clean and check the Tool Blocks in the event of feed problems.

STORAGE

If the Clamshell is to be stored or if it will remain out of service for a significant

period of time (30 days or more), it should be thoroughly cleaned lubricated and

sprayed with a rust preventative prior to storage.

Remove the airline Quick Disconnect and spray it with a lightweight oil.

Squirt oil into the male Quick Disconnect.

Reconnect the airline and turn on the Air Motor for 1 or 2 seconds to disperse oil

throughout the vanes and rotor.

ADJUSTMENT OF THE MAIN BEARING PRE-LOAD

Loosen all Bearing Adjustment Lock Screws (A through F).

Loosen all Bearing Adjustment Set Screws about ½ turn. (1 through 12).

Turn in Bearing Adjustment Set Screws (1, 4, 7, and 10) so that they are snugged

tightly. This insures that the Bearing is fully pushed forward. Refer to the Bearing

Adjustment Screw locations.

Advertising