Configuration

3-18

Verilink SCC 2130 User Manual

The top line of the SCC 2130 Main Menu indicates which version of
firmware is currently running and the second line indicates which
flashbank the current firmware was loaded from. To determine
which version of firmware is in the other flashbank, use the boot
option on the Node Administration Menu and select that
flashbank.

You will need to

know

The IP address of the FTP server

The absolute path to the directory containing the Verilink SCC
upgrade files

The password, if required, for accessing the FTP server

NOTE: If you received the Verilink SCC files in a PKZIPped format,

first extract them using PKUNZIP. Two files may be found,

FLASH.A and FLASH.B. For this procedure only FLASH.B is

required.

Step by Step

1. Using either direct connection to the Craft port, or Telnet,

open a Craft session to the SCC card to be upgraded

2. Use the O command to select the Node Administration Menu

3. Type “B” to reboot.

NOTE: The boot command reboots only the SNMP and Craft

interface functions of the SCC 2130, any user data passing

through the SCC 2130 will not be affected.

4. Select flashbank A

5. When the

pSH+>

pSH+>

pSH+>

pSH+> prompt returns type “FTP <IP address of FTP

server>”

6. Login to the FTP server using the method required by your FTP

server program

7. Use the CD command to change to the directory where you

previously placed the file FLASH.B

8. Use DIR or ls -l, as appropriate, to produce a long display of

the files in this directory

9. Record the file size of the FLASH.B file

10. Issue the command “binary”

NOTE: If you fail to issue the command “binary”, the file will be

corrupted when it is transferred.

11. Issue the command “get flash.b flash.hex”.