Thumbwheel switches, Thumbwheel procedure, Thumbwheel switches -21 – Verilink SCC 2130 (880-503282-001) Product Manual User Manual

Page 41: Thumbwheel procedure -21, Table 3-7

Advertising
background image

Configuration

Verilink SCC 2130 User Manual

3-21

Table 3-7

Element Download Commands

Thumbwheel Switches

The thumbwheel switches on the front of the SCC 2130 module are
provided as a measure of last resort for configuring the SCC,
and/or application modules it controls, when terminal access to
the Craft interface is not possible.

It is preferred practice to use the Craft interface, a Telnet session,
or an SNMP manager instead of the thumbwheels.

The SCC 2130 is able to control up to 51 other modules in up to 4
shelves. The thumbwheel switches are only able to address the first
30 slots, thus it is not possible to use thumbwheel commands to
configure a module if it is in the 31st to 52nd slot of a four shelf
node.

Thumbwheel

Procedure

A four-step procedure is used for each thumbwheel command:

1. Set the thumbwheel to the number, 01 through 30, equal to the

slot number of the module to be optioned. If a node consists
of Multi-line shelves, the first slot in shelf two would be

Menu Option

Description

Instructions

T) element

Selects type of module to be

upgraded, a list is

presented

To upgrade the IDCSU

portion of an SCC 2130,

select TAC 2130

Selections 9 and 10 will not

function unless the sites are

connected with an ESF T1

which has a continuous

Facilities Data Link (FDL)

link between them

To test for a continuous

FDL, attempt to reach the

Far Element from the Main

Menu

(1)TAC 2010 — a TAC 2010 CSU or an SCC 2020

(2)TAC 2130 — An IDCSU (Integrated DSU/CSU)

(3)TAC 2110 — an Automatic Protection Switch (APS)

CSU

(4)DIU 2130 — A two-port DSU module

(5)DIU/NMS — A modified DIU 2130 which supports

mapping done by the carrier to DDS remote circuits

(6)DIU/DBU — Modified DIU 2130 which supports

external dial-backup function

(7)DDS 2140 — a DIU 2140 subrate data multiplexer 5

port RS-232 DSU

(9)FAR TAC 2130 — an IDCSU at a remote site

(10)FAR TAC 2110 — an APS CSU at a remote site

(11)DIU/HLM — a DIU 2131, V.35+RS-232 two-port DSU

F) file

Name of the upgrade file

Use the name as it was supplied by Verilink

S) shelf

Shelf or range of shelves

Enter a single number or a range as in: 1-4

L) slot

Slot or range of slots

Enter a single number or a range as in: 1-13

D) dwnload

Starts the download

Set all other parameters first, then issue the D command

X) exit menu

Exits to menu above

Returns to

Node Administration Menu

Advertising