2 set-up – Watson-Marlow Bredel 265 User Manual

Page 24

Advertising
background image

INSTALLATION

24

For extreme conditions, special precautions must be
taken. Contact your local Bredel representative for
additional information.

5.3.2

Set-up

The pump materials and protective layers are
suitable for indoor set-up and a protected
outdoor set-up. Under certain conditions the
pump is suitable for limited outdoor set-up or a
salty or aggressive atmosphere. Consult your
Bredel representative for more information.

Position the pump on a horizontal surface. Use
suitable anchor bolts to attach the pump to the
floor surface.

Make sure that there is sufficient room around
the pump to carry out the necessary
maintenance activities.

Make sure that the room is sufficiently
ventilated, so that the heat developed by the
pump and drive can be discharged. Keep some
distance between the ventilation cover of the
electric motor and wall to enable the supply of
necessary cooling air.

A qualified electrician who is fully conversant
with the appropriate regulations should connect
the electric motor.

Motor wiring: Follow the guidelines issued by
the motor manufacturer. A current overload
relay should be fitted to a contact breaker.
Connect the motor in accordance with the
manufacturer's instructions. When a thermal
protection switch is fitted in the motor, the leads
will be found in the motor terminal box. They
should be connected to stop the pump if the
switch changes state.

A qualified electrician who is fully conversant
with the appropriate regulations should connect
liquid level switches and/or revolution counter.

max 0.12”/ft

1ft

Advertising