2 fitting a low level float switch – Watson-Marlow Bredel 265 User Manual

Page 63

Advertising
background image

MAINTENANCE

63

8.9.2

Fitting a low level float switch

1.

If the pump is filled with lubricant this must be
removed first. Place a clean tray (A) under the
drain plug in the bottom of the pump. Remove
the drain plug (B). Catch the lubricant from the
pump housing in the tray. Check the sealing ring
(C) for damage.

2.

Fit the crimp connector (A) together with the
sealing ring (B) to the pump housing. Fit the
low-level float switch (C) to the crimp connector
(A).

3.

Connect the low-level float switch to the
electrical supply. Bear in mind that the electrical
contact of the float switch is normally closed
(NC). When the lubricant level is (too) low the
contact will open.

4.

Refill the pump housing to the proper level with
Bredel Genuine Hose Lubricant.

A

B

C

B

A

C

D

Specifications

Voltage:

Max. 230 V AC/DC

Current:

Max. 2 A

Power:

Max. 40 VA

Where the floater is constructed to stop the
equipment, operating has to be arranged
so that the stop function locks-out, prevent-
ing the equipment from being re-started
without re-setting. Check if the floater is
mounted with the NC sign at the top.