Supply voltage/frequency

100-120V/200-240V 50/60Hz 1ph

Maximum voltage fluctuation

±10% of nominal voltage. A well

regulated electrical mains supply is re-

quired along with cable connections con-

forming to the best practice of noise

immunity

Installation category
(overvoltage category)

II

Power consumption

100VA

Full load current

<0.43A at 230V; <0.86A at 115V

Eprom version

Accessible through pump software

Enclosure rating

IP31 to BS EN 60529; Equivalent to

NEMA 2. Suitable for indoor use. Pro-

tected against dripping water and falling

dirt. May be wiped with a damp cloth but

should not be immersed

Operating temperature range

4C to 40C, 40F to 104F

Storage temperature range

-40C to 70C, -40F to 158F

Maximum altitude

2,000m, 6,560ft

Humidity (non-condensing)

80% up to 31C, 88F, decreasing

linearly to 50% at 40C, 104F

Weight

See 8.2 Dimensions

Noise

<70dB(A) at 1m

Pump specifications

Absolute minimum dose size

Two revolutions

Recommended minimum dose size

Five revolutions

Maximum single dose size

9,999 litres

Minimum number of doses

1

Maximum number of doses

9,999

Minimum interval between doses

0.1 second

Maximum interval between doses

999 seconds