17

We recommend using commercially available supply
voltage surge suppression where there is excessive elec-
trical noise.

10 Connecting this product
to a power supply

A well regulated electrical mains supply is required along with cable connections con-
forming to the best practice of noise immunity. It is not recommended to site these
drives alongside “dirty” electrical mains supplies such as 3-phase contactors and in-
ductive heaters without special attention being paid to unacceptable mains-borne
noise.

The voltage selector is mounted in the switchplate at the rear of
the pump. Set the voltage selector to 115V for 100-120V
50/60Hz supplies or 230V for 200-240V 50/60Hz supplies. Al-
ways check the voltage selector switch before connecting the
mains supply. Make suitable connection to an earthed, single-
phase mains electricity supply. To comply with Safety Standards,

the mains plug must be a separable plug (not a locking type).

Input line fusing: type T1.0AH 250V 20mm time-delayed cartridge fuse, located in
the combined mains IEC inlet socket and fuse drawer at the rear of the pump.

Note: A spare fuse is also provided in the drawer.

Conductor coding

European

North American

live

brown

black

neutral

blue

white

ground

green/yellow

green