1 error messages – Watson-Marlow 323Dz User Manual

Page 39

Advertising
background image

Watson-Marlow 323Dz User Manual

39

Error

Error condition

Suggested action

0

RAM write error

Attempt to reset by switching power OFF / ON.
Or seek support

1

RAM corruption

Attempt to reset by switching power OFF / ON.
Or seek support

2

OTP ROM error /
corruption

Attempt to reset by switching power OFF / ON.
Or seek support

3

OTP ROM read
error

Attempt to reset by switching power OFF / ON.
Or seek support

5

Unknown pump
type

Check the interface card and cables. Attempt to
reset by switching power OFF / ON. Or seek support

7

Display failure

Seek support

8

Wrong key-press

Attempt key-press again. Attempt to reset by
switching OFF / ON

9

Motor stalled

Stop pump immediately. Check pumphead and
tube. Power OFF/ON may reset. Or seek support

10

Tacho fault

Stop pump immediately. Power OFF/ON may reset.
Or seek support

14

Over speed

Stop pump immediately. Power OFF/ON may reset.
Or seek support

15

Over current

Stop pump immediately. Check system. Power
OFF/ON may reset. Or seek support

16

Over voltage

Stop pump immediately. Check mains voltage se-
lector switch. Check supply. Power OFF/ON may
reset. Or seek support

17

Under voltage

Stop pump immediately. Check mains voltage se-
lector switch. Check supply. ON/OFF may reset. Or
seek support

18

Watchdog error

Attempt to reset by switching power OFF / ON.
Or seek support

19

Over temperature

Stop pump immediately. Turn OFF. Seek support

20

Signal out of
range

Check analogue control signal range. Trim signal as
required. Or seek support

21

Over signal

Reduce the analogue control signal

22

No signal

Connect analogue control signal or return to manual
control

25

Network not
detected

Turn OFF. Check network and connections. Or seek
support

26

RS232 fault

Turn OFF. Check network and connections. Or seek
support

27

RS232 lost

Turn OFF. Check network and connections. Or seek
support

33

Unrecognised
keypress

Attempt keypress again. Attempt to reset by
switching power OFF/ON. Otherwise seek support.

35

Work overload

Turn OFF. Check power supply. Check pumphead
and tubing. Wait 30 minutes. Power ON may reset.
Otherwise seek support.

ERR

General error
condition

Turn OFF. Seek support

16.1 Error messages