Result codes – Westermo TD-32 User Manual

Page 35

Advertising
background image

35

6178-2203

Result Codes

When a command is sent from the terminal the modem replies with a result code. The reply may be
either in Long Form i.e. text (V1) or in Short Form, i.e. a two digit code (V0). The result code in
Long Form is followed by <CR><LF> and in Short Form by <CR>. Using the Q1 command enables
the result codes. The result codes and their short forms are as follows:

00

OK

The OK code is returned to acknowledge execution of a
command line.

01

CONNECT

The modem will send this result code upon connecting
with 300 baud.

02

RING

Incoming ringing is detected on the line.

03

NO CARRIER

No carrier is detected.

04

ERROR

The modem will send this result code when it’s unable to
execute a command contained on the command line.

05

CONNECT 1 200

For connections with 1 200 baud.

06

NO DIALTONE

No dial tone is received.

07

BUSY

Busy (engaged) signal is detected on the line.

08

NO ANSWER

No answer from remote modem detected on the line until
the expiration of the time S7.

09

CONNECT 600

For connections with 600 baud on the DTE.

10

CONNECT 2 400

For connections with 2 400 baud on the DTE.

11

CONNECT 4 800

For connections with 4 800 baud on the DTE.

12

CONNECT 9 600

For connections with 9 600 baud on the DTE.

16

CONNECT 19 200

For connections with 19 200 baud on the DTE.

17

CONNECT 38 400

For connections with 38 400 baud on the DTE.

18

CONNECT 57 600

For connections with 57 600 baud on the DTE.

24

DELAYED

If dialled number not allowed to dial yet.

32

BLACKLISTED

If dialled number is not allowed.

33

FAX

If it’s a fax connection.

34

+FCERROR

Error in fax connections.

35

DATA

Connected as data modem.

40

CARRIER 300

300 baud carrier.

42

CARRIER 600

600 baud carrier.

46

CARRIER 1 200

1 200 baud carrier.

47

CARRIER 2 400

2 400 baud carrier.

48

CARRIER 4 800

4 800 baud carrier.

49

CARRIER 7 200

7 200 baud carrier.

50

CARRIER 9 600

9 600 baud carrier.

51

CARRIER 12 000

12 000 baud carrier.

52

CARRIER 14 400

14 400 baud carrier.

66

COMPRESSION: CLASS 5

MNP class 5 compression active.

67

COMPRESSION: V.42 bis

V.42 bis compression active.

69

COMPRESSION: NONE

No compression active.

70

PROTOCOL: NONE

No error correction active.

77

PROTOCOL: LAPM

LAPM error correction active.

80

PROTOCOL: ALT

MNP4 error correction active.

81

PROTOCOL: ALT-CELLULAR

MNP10 with Cellular active.

100

NOVRAM ERROR

Error in memory.

101

NO NOVRAM

No memory mounted.

102

SWITCH ERROR

Error in switches.

103

INACTIVITY TIMEOUT

Inactivity time limit reached.