6178-2203

S9 – Carrier Detect Response Time
Sets the time that the carrier must be present before a connection is established.
Default 6 {1..255} (1/10 sec).

S10 – Lost Carrier To Hang Up Delay
Sets the length of time that the modem waits before hanging up after a loss of carrier.
When register S10 is set to 255, the modem functions as if a carrier were always present.
Default 14 {1..255}(1/10 sec).

S11 – DTMF tone time
The time a DTMF tone will be activated during dialling.
Default 95 {50..255} (1/1000 sec).

S12 – Escape Prompt Delay (EPD)
Time before entry/exit of command mode (+++).
Default 50 {0..255}(1/50 sec).

S14 – General Bit Mapped Options Status (Read only register)

Bit Interval

Default

Description

0

0

Reserved

1

0..1

1

Command echo:

0-Echo Disabled (ATE0)
1-Echo Enabled (ATE1)

2

0..1

0

Result Codes:

0-Send Result Codes (ATQ0)
1-Do Not Send Result Codes (ATQ1)

3

0..1

1

Result Code Control:

0-Numeric (ATV0)
1-Verbose (ATV1)

4

0..1

0

Reserved

5

0..1

0

Tone/Pulse:

0-Tone
1-Pulse

(Please also refer to Dn – Dial
Command p. 17)

60..1

0

Reserved

7

0..1

1

Originate/Answer:

0-Answer
1-Originate