Westermo TD-32 User Manual

Page 43

Advertising
background image

43

6178-2203

S38 – Delay Before Forced Hang Up (Not stored with the AT&W command)
This register specifies the delay between the modem’s receipt of the H command to disconnect (or
ON-to-OFF transition of DTR if the modem is programmed to follow the signal), and the disconnect
operation. This register can be used to ensure that data in the modem buffer is sent before the modem
disconnects. 255 makes the modem stay connected until the buffer is empty, or the carrier is lost.
Default 20 {0-255} (seconds).

S39 – Bit mapped register (Read Only Register)

Bit

Interval

Default

Description

0..2

0,3..6

3

Flow control:

0-No flow control (AT&K0)
3-RTS/CTS flow control (AT&K3)
4-XON/XOFF flow control (AT&K4)
5-Transparent XON/XOFF
flow control (AT&K5)
6-RTS/CTS and XON/XOFF
flow control (AT&K6)

3..7

Reserved

S40 – Bit mapped register (Read Only Register)

Bit

Interval

Default

Description

0

0..1

0

MNP extended services:

0-No conversion from V.42 to MNP10
(AT-K0)
1-Conversion from V.42 to MNP10
(AT-K1)

1

0..1

0

”Cellular” MNP10 effect level
adjustment:

0-Non effect level adjustment (AT)M0)
1- effect level adjustment during
MNP10 negotiation (AT)M1)

2

0..1

0

MNP connect speed:

0-Negotiation with highest possible
speed (AT*H0)
1-Negotiation with 1200 Baud
(AT*H1)

3..5

0..5

5

”Break” handling:

0-AT\K0
1-AT\K1
2-AT\K2
3-AT\K3
4-AT\K4
5-AT\K5

6..7

0..3

2

MNP block size:

0-64 characters (AT\A0)
1-128 characters (AT\A1)
2-192 characters (AT\A2)
3-256 characters (AT\A3)

Advertising