Westermo TD-32 User Manual

Page 44

Advertising
background image

44

6178-2203

S41 – Bit mapped register (Read Only Register)

Bit

Interval

Default

Description

0..1

0..3

3

Compression selection:

0-No compression (AT%C0)
1-MNP5 (AT%C1)
2-V.42bis (AT%C2)
3-MNP5 or V.42bis (AT%C3)

2

0..1

1

Automatic line quality and fall back/fall forward:

0-Line quality and fall back/fall forward disabled
(AT%E0)
1- Line quality and fall back/fall forward enabled
(AT%E1)

3

0..1

0

Modem-to-modem flow control:

0-No flow control (AT\G0)
1-Modem-to-modem flow control (AT\G1)

4

0..1

0

MNP block or character stream control:

0-Character stream (AT\L0)
1-Blockmode (AT\L1)

5..7

0..7

0

Reserved

S46 – V.42bis Data compression control
136 – No data compression
138 – V.42bis data compression
Default 138 {136,138}.

S48 – V.42 Negotiation Control
0 – Force LAPM connection
7 – Enable negotiation
128 – Force value as specified in S36
Default 7 {0,7,128}.

Please also refer to S36

S82 – Break-control for LAPM connections (Not stored with &W)
3 – Break is sent immediately. Data in the buffer is stored.
7 – Break is sent immediately. Data in the buffer is destroyed.
128 – Break is buffered
Default 128 {3,7,128}.

S86 – Call failure indication (Read Only Register, not stored with &W)
This register contains an indication of what went wrong after a dialling error.
Default 0 {0..255}.

S91 – PSTN Transmit level (Directly stored in NVRAM)
Default 13 Default value and interval is country dependant {0..30} (dBm)

Advertising