0x1ef00), Proprietary: simulate mode – Airmar PB200 User Manual
Page 32

PB200 WeatherStation User Manual revision 1.000
Proprietary and Confidential
26
NMEA 2000® TRANSMITTED PARAMETER GROUP
PGN
126720-35
(0x1EF00)
Proprietary: Simulate Mode
Single Frame: No
Priority: 7/Y/N
Update Rate: 0/N/N
Destination: Address
Query Support: Yes
Access Level: 1
Field
#
Name
Request
Param. DD
DF
Type Resolution
Value
Remark
1 Manufacturer Code
Yes
DD172 DF52 11 bits
1
135 (decimal)
Manufacturer Code for Airmar Technology.
2 Reserved bits
No
DD001 DF52 2 bits
1
0x3
All bits set to logic "1"
3 Industry Group
Yes
DD168 DF52 3 bits
1
4 (decimal)
Industry Group for "Marine Industry".
4 Proprietary ID (PID)
Yes
DD005 DF53 uint8
1 bit
35 (decimal)
35 = Simulate Mode
5 Simulate Mode
No
DD003 DF52 2 bits
1
MSB/LSB:
00 = Simulate Mode Off
01 = Simulate Mode On
10 = Reserved
11 = No action/Data Not
Available
This field defines whether the PB200 is in
Simulate Mode.
This field may be changed with the Command
Group Function PGN 126208. It is not saved in
EEPROM. The default value on power up is 00
(Simulate Mode Off).
6 Reserved bits
No
DD001 DF52 22 bits
1
0x3FFFFF
All bits set to logic "1"
Notes
This PGN is transmitted in response to a PGN 126208 Request Group Function message. Fields 1, 3, and 4 must each be fully specified in the request in order for this PGN to be
transmitted.
This PGN does not respond to ISO Requests (PGN 59904).
Although this is a fast-packet message, the version with this PID fits into a single CAN frame.
(continued on next page)