0x1ff41), Proprietary: heater control – Airmar PB200 User Manual
Page 64

PB200 WeatherStation User Manual revision 1.000
Proprietary and Confidential
58
NMEA 2000® TRANSMITTED PARAMETER GROUP
PGN
130881
(0x1FF41)
Proprietary: Heater Control
Single Frame: No
Priority: 7/Y/Y
Update Rate: 0/Y/Y
Destination: Global
Query Support: Yes
Access Level: 0
Field
#
Name
Request
Param. DD
DF
Type Resolution
Value
Remark
1 Manufacturer Code
Yes
DD172 DF52 11 bits
1
135 (decimal)
Manufacturer Code for Airmar Technology.
2 Reserved bits
No
DD001 DF52 2 bits
1
0x3
All bits set to logic "1"
3 Industry Group
Yes
DD168 DF52 3 bits
1
4 (decimal)
Industry Group for "Marine Industry".
4 PG Transmit Option
No
N/A DF52 2 bits
1
MSB/LSB:
00 = Do not transmit on
status change
01 = Transmit on status
change
10 = Error
11 = Data not available
This field defines whether this PGN is
transmitted automatically when there is a
change in the heater status (field 6) while the
heater mode (field 5) is in Automatic.
This field is stored in EEPROM and may be
changed with the Command Group Function
PGN 126208. The default value is 00 (do not
transmit on status change).
5 Heater Mode
No
N/A DF52 2 bits
1
MSB/LSB:
00 = Manual, Turn Off
01 = Manual, Turn On
10 = Automatic
11 = No action
This field is stored in EEPROM and may be
changed with the Command Group Function
PGN 126208. If the Heater Mode is 01 upon
power up, the heater will not be turned On, i.e.
the unit will behave as though the Heater Mode
is 00. If the Heater Mode is 10 (Automatic)
upon power up, the heater will cycle on and off
automatically over time as required to maintain
the proper plate temperature.
The default value is 00 (Manual, Turn Off).
6 Heater Status
No
DD002 DF52 2 bits
1
MSB/LSB:
00 = Off
01 = On
10 = Error
11 = Data not available
This field indicates the actual state of the heater.
The power up default value is 00 (Off). The
PB200 will return DataNotAvailable unless the
Heater Control option is enabled at the factory.
7 Reserved bits
No
DD001 DF52 2 bits
1
0x3
All bits set to logic "1"
8 Plate Temperature
No
DD043 DF39 uint16 0.01 deg K 0 to 655.32 deg K
Temperature of the aluminum plate at the base
of the PB200 wind channel.