NMEA 2000® RECEIVED PARAMETER GROUP

_

PGN

065286

(0x0FF06)

Proprietary: Boot State Request

Single Frame: Yes

Access Level: 0

Field

#

Name

DD

DF

Type Resolution

Value

Remark

1 Manufacturer Code

DD172 DF52 11 bits

1

135 (decimal)

Manufacturer Code for Airmar Technology.

2 Reserved bits

DD001 DF52 2 bits

1

0x3

All bits set to logic "1"

3 Industry Group

DD168 DF52 3 bits

1

4 (decimal)

Industry Group for "Marine Industry".

4 Reserved bits

DD001 DF52 48 bits

1

0xFFFFFFFFFFFF

All bits set to logic "1"

Notes
When this destination global PGN is received by the PB200, the unit will respond by transmitting PGN 65285 (see). It is intended that all Airmar devices connected to the

NMEA 2000® bus will likewise also reply accordingly when receiving this PGN.