# Start the test.

[Sysname-hwping-administrator-ftp] test-enable

# Display test results

[Sysname-hwping-administrator-ftp] display hwping results administrator ftp

HWPing entry(admin administrator, tag ftp) test result:

Destination ip address:10.2.2.2

Send operation times: 10 Receive response times: 10

Min/Max/Average Round Trip Time: 3245/15891/12157

Square-Sum of Round Trip Time: 1644458573

Last complete test time: 2000-4-3 4:0:34.6

Extend result:

SD Maximal delay: 0 DS Maximal delay: 0

Packet lost in test: 0%

Disconnect operation number: 0 Operation timeout number: 0

System busy operation number: 0 Connection fail number: 0

Operation sequence errors: 0 Drop operation number: 0

Other operation errors: 0

[Sysname-hwping-administrator-ftp] display hwping history administrator ftp

HWPing entry(admin administrator, tag ftp) history record:

Index Response Status LastRC Time

1 15822 1 0 2000-04-03 04:00:34.6

2 15772 1 0 2000-04-03 04:00:18.8

3 9945 1 0 2000-04-03 04:00:02.9

4 15891 1 0 2000-04-03 03:59:52.9

5 15772 1 0 2000-04-03 03:59:37.0

6 15653 1 0 2000-04-03 03:59:21.2

7 9792 1 0 2000-04-03 03:59:05.5

8 9794 1 0 2000-04-03 03:58:55.6

9 9891 1 0 2000-04-03 03:58:45.8

10 3245 1 0 2000-04-03 03:58:35.9

For detailed output description, see the corresponding command manual.

If you are downloading a file from the server, you do not need to specify an FTP operation type. For

details, see section

Configuring FTP test on HWPing client

.

HTTP Test

Network requirements

An H3C S3100 series Ethernet switch serves as the HWPing client, and a PC serves as the HTTP

server. Perform an HWPing HTTP test between the switch and the HTTP server to test the connectivity

and the time required to download a file from the HTTP server after the connection to the server is

established.