To configure a combo interface:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter view of the SFP port or
RJ-45 port of the combo

interface.

interface interface-type
interface-number

N/A

3.

Activate the RJ-45 Ethernet
port or SFP port.

combo enable { copper | fiber } By default, the fiber port is active.

Displaying and verifying transceiver modules

Table 18 Commonly used transceiver modules

Transceiver module type

Application scenarios

Whether can be

an optical

transceiver

Whether can be

an copper

transceiver

SFP (small form-factor
pluggable)

Generally used for
100M/1000M Ethernet

interfaces or POS
155M/622M/2.5G interfaces.

Yes. Yes.

XFP(10-Gigabit small

form-factor pluggable)

Generally used for 10G

interfaces.

Yes. No.

SFP+ (enhanced small
form-factor pluggable)

Generally used for 10G
interfaces.

Yes. No.

Displaying transceiver module information

To identify transceiver modules, you can use the following command to view the key parameters of the

transceiver modules, including transceiver module type, connector type, central wavelength of the laser

sent, transmission distance, and vendor name or name of the vendor who customizes the transceiver

modules.
To display transceiver module information:

Task Command

Remarks

Display key parameters of the
transceiver module in a specified

interface.

display transceiver interface
[ interface-type interface-number ]

Available for all transceiver
modules.

Verifying transceiver modules

The system outputs alarm information for you to locate and troubleshoot faults of transceiver modules. For

the H3C-customized transceiver modules, the system can also monitor the key parameters, such as

temperature, voltage, laser bias current, TX power, and RX power. When these parameters are abnormal,

you can take corresponding measures to prevent transceiver module faults.
To display the alarming information or fault detection parameters of a transceiver module: