Troubleshooting, Troubleshooting the power system, Troubleshooting the configuration system – H3C Technologies H3C MSR 30 User Manual

Page 96: Troubleshooting the console terminal

Advertising
background image

88

Troubleshooting

Troubleshooting the Power System

Symptom:
The PWR LED RUN is OFF or blinking.
Solution:
Check that:

•

The power switch on the router is turned on.

•

The switch of the power source is turned on.

•

The power cord is correctly connected.

•

The power source meets the requirement of the router.

Troubleshooting the Configuration System

If the router passes POST after powered up, the console screen displays the startup banner; if faults occur

to the configuration system, the console screen displays nothing or only illegible characters.

Troubleshooting the console terminal

Symptom:
After the router is powered on, the console screen displays nothing.
Solution:
Step 1: Check that:

•

The power system is normal.

•

The console cable is correctly connected.

Step 2: Check the console cable and the terminal (HyperTerminal for example) settings.

Troubleshooting the console terminal

Symptom:
After the router is powered on, the console screen displays illegible characters.
Solution:
Verify that the terminal settings are as follows:

•

Baud: 9600

•

Data bits: 8

•

Stop bit: 1

•

Parity: None

•

Flow control: None

•

Terminal emulation: VT100