Pdx218 scsi cable connections – Grass Valley PDX 218 User Manual

Page 27

Advertising
background image

PDX218 SCSI Cable Connections

PDX 218 Instruction Manual

2-9

Two PDX218s Connected to a Profile System with Two Disk Recorder Boards

Figure 2-9 shows a PDX 218 connected to a Profile system with Master and Slave
Disk Recorder boards installed. The location of the Disk Recorder boards may be
different than shown in Figure 2-9. To locate the Disk Recorder boards in your
system, see the rear panel board slot labels.

To connect two PDX218s, refer to Figure 2-6 and Figure 2-9 and:

1. Connect a SCSI cable from the first PDX218 SCSI Bus 2 connector to the Profile

system rear panel connector in the slot labeled DISK RECORDER Master.

2. Connect a SCSI cable between the SCSI Bus 1 and SCSI Bus 2 connectors on the

first PDX 218.

3. Connect a Terminator to the unused SCSI Bus 1 connector on the first PDX 218.

4. Connect a SCSI cable from the second PDX218 SCSI Bus 1 connector to the

Profile system rear panel connector in the slot labeled DISK RECORDER Slave.

5. Connect a SCSI cable between the SCSI Bus 1 and SCSI Bus 2 connectors on the

second PDX 218.

6. Connect a Terminator to the unused SCSI Bus 2 connector on the second PDX 218.

Figure 2-9. Connecting Two PDX218s to a Profile System with Master and Slave Disk Recorder Boards

The connection shown in Figure 2-9 provides eight 18GB disk drives to the SCSI A
bus and eight 18GB disk drives to the SCSI C bus on the Profile system (or SCSI A
and SCSI B bus on the PDR100).

9687-24

Terminator

SCSI Cable

First PDX218

Second PDX218

Profile Video
File Server

Disk

Recorder

Master

Disk

Recorder

Slave

Note:
Disk recorder board locations may be
different than shown. See rear panel
labels for actual locations.