Troubleshooting, Power on indicator, Troubleshooting -4 – Grass Valley PDX 218 User Manual

Page 38: Power on indicator -4, Pdx218 front panel indicators -4

Advertising
background image

Chapter 3 Service

3-4

PDX 218 Instruction Manual

Troubleshooting

If you suspect that the PDX 218 is the cause of a Profile-related problem:

• Check all SCSI cable connections.

• Check the power cord connection.

• Insure the On/Off switch is On.

• Insure that the power switch and line filter are good.

• Check the indicators on the front panel (Figure 3-2) which provide information to

assist in fault isolation.

If it is necessary to replace a component, see Removal and Replacement Procedures
later in this chapter.

Refer to Figure 3-2 in the following discussions.

Figure 3-2. PDX218 Front Panel Indicators

Power On Indicator

The chassis power green LED indicator should be On.

If Off

- Power Supply bad, replace Power Supply.
- Fuse F1 or F3 on SCSI Distribution board blown, replace SCSI Distribution

board.

- LED cable assembly bad, replace cable assembly.

9687-7

Power On LED

Disk activity

LEDs

Fan failure LED

(located behind bezel)

System fault

LED