7 Modbus TCP/IP Messaging

36

YASKAWA ELECTRIC TOBP C730600 57B 1000-Series Option SI-EM3 Installation Manual

Table 8 Drive Registers

Address

(hex)

Drive

Register

(hex)

Description

Bit

Description

2000

4B

Status Word

(U1-12)

0

During Run

1

During Zero Speed

2

During Reverse Direction

3

During Fault Reset Signal Input

4

During Speed Agree

5

Drive Ready

6

Alarm

7

Fault

8

During Operation Error (oPE††)

9

During Momentary Power Loss

A

Motor 2 Selected

B

Reserved

C

Reserved

D

Reserved

E

ComRef Status, NetRef Status

F

ComCtrl Status, NetCtrl Status

2001

44

Motor Speed Monitor (U1-05)

2002

48

Torque Reference Monitor (U1-09)

2003

F0

PG Count Channel 1

2004

40

Frequency Reference Monitor (U1-01)

2005

41

Output Frequency Monitor (U1-02)

2006

26

Output Current
(0.01 A units for drives set to 11 kW in Heavy or Normal Duty and 0.1 A units for drives
set to 15 kW and above.)

2007

4F

Terminal A2 Input Level Monitor (U1-14)

2008

46

DC Bus Voltage Monitor (U1-07)