4.6 Faults

Fault Display

Description

Cause

Countermeasures

ZDEV

Marker Pulse

Detection Error

The drive monitors the number of A and
B channel encoder pulses between each
marker pulse (Z or C channel). There
should be P1-02 (Encoder PPR) A and B
channel pulses between each marker
pulse. If the pulse count exceeds P1-02
x 2, the drive will trip and coast to a stop
on a ZDEV fault.

-Check the wiring of the
encoder, especially the Z pulse.

-Check for noise on the encoder
feedback signals.



5.0 Function Description

5.1 Orient Position Offset Selection Using Parameter P2-01

a. P2-01 = 0 (Offset = P1-03)

b. P2-01 = 1 (Offset = P1-03, P2-02, P2-03, or P2-04 by Sequential Orientation Command)










Sequential Offset by Successive Orientation Command


c. P2-01 = 2 (Offset = P1-03, P2-02, P2-03, or P2-04 by MFDI selection)

Multi-function Digital Input (H1-0X) Selection

Parameter Number

Step

85: Offset Selection 2

84: Offset Selection 1

P1-03: Marker Offset

0

Open

Open

P2-02: Offset 1

1

Open

Closed

P2-03: Offset 2

2

Closed

Open

P2-04: Offset 3

3

Closed Closed


d. P2-01 = 3 (Offset = Serial Offset: Modbus register 000AH)

5.2 Selecting Motor Gear Ratio Parameters P2-05, P2-06, and P2-07

Multi-function Digital Input (H1-XX) Selection

Parameter Number

87: Motor Ratio Selection 2

86: Motor Ratio Selection 1

P2-05:

Motor Gear Ratio 1

Open

Open

P2-06:

Motor Gear Ratio 2

Open

Closed

P2-07:

Motor Gear Ratio 3

Closed

Open

Not Used

Closed Closed

Orient Command

Sequential Step

Selected Offset

P1-03

P2-02

P2-03

P2-04

P1-03

P2-02

Advertising