4.2 Monitors (U1-XX)

Monitor Number

Modb

us Addr

e

ss

Monitor Name

Digital Operator

Display

Description

Scaling for

Multi-function

Analog Output

Terminals

FM and AM

(H4-01, H4-04)

Unit

Access Level For All

Contro

l Modes

*1

U1-90 720H

Marker Offset

Marker Offset

Displays the current number of
quadrature orientation encoder
counts the machine is past the
marker pulse. See parameter P1-
02.

The display range is 0 ~ 32,768
counts.

Note: Counts = Encoder PPR x 4.

NA Counts

A

U1-91 721H

Shaft Angle

Shaft Angle

Displays the angle in degrees the
machine is away from the active
orientation position offset.

The display range is 0.0 ~ 359.9º.

NA º

A

U1-92 722H

Sequence Offset

Seq Offset

Displays the active value of the
orientation offset from the marker
pulse. See parameter P2-01 and
section 5.1.

The display range is 0 ~ 8192
counts.

Note: Counts = Encoder PPR x 4.

NA Counts

A

U1-93 723H

Sequence Step

Sequence step

Displays the active orientation
offset parameter. See parameter
P2-01 and section 5.1 for more
information.

The display range is 0 ~ 3.

0: P1-03
1: P2-02
2: P2-03
3: P2-04

NA -

A

U1-94 724H

Serial Offset

Serial Offset

Displays the orientation position
offset from the marker pulse when
P2-01 = 3. This monitor reflects the
data in Modbus register 000AH.
See parameter P2-01 and section
5.1 for details.

The display range is 0 ~ 8192
counts.

NA Counts

A

*1: Access Level (A1-01): Q = “Quick Start”, A = “Advanced”, F = “Factory”.