Function
Controls
Range
Default
Setup
F1-01: PG Pulses/Rev.
0 to 60000
1024
Requires a PG option card
PG Channel 1
E2-02: Motor Poles
2 - 48
4
Flux Vector control only
PG Channel 2
P2-01: Max Pulses In 2
0 to 65535
30720
Requires a PG-W2 card
2.1.5 10000
The 10000 function outputs the number 10000 to all connected functions.
2.1.6 0
The 0 function outputs the number 0 to all connected functions.
2.1.7 Drive
Output
The Drive Output function outputs the percentage of the maximum frequency setting that the
drive is outputting. The value output can range from 0 to 10000.
2.1.8 Drive Output Torque
The Drive Output Torque function outputs the percentage of the drive output torque. The value
output can range from 0 to the maximum torque setting.