0 parameter changes, 3 group h terminal - function h1 digital inputs, 4 function h2 digital outputs – Yaskawa G5 Eliminator User Manual

Page 19: 5 function h4 analog outputs, 6 group f options

Advertising
background image

Date: 07/01/04, Rev: 04-07

Page 19 of 27

TM.G5SW.015

3.0 Parameter

Changes



3.1

Group A User Parameters


The user parameters are located within the “Initialize” menu selection. When the GPD515/G5
drive has been flashed with this software A2-11 through A2-32 constants are converted to the
parameters used to configure the drive.


3.2

Group b Applications – Function b1 Sequence

Display Constant

Setting

Display Description

Reference Source

b1-01

05

Eliminator Ref

Enables the Eliminator Software



3.3

Group H Terminal - Function H1 Digital Inputs

Display Constant

Setting

Display Description

80

Switch 1 DI

Switch function with a common output to a NO and NC input

81

Switch 2 DI

Switch function with a common output to a NO and NC input

82

MOP UP

Increases the MOP value

83

MOP DOWN

Decreases the MOP value

84

MOP RESET

Resets the MOP value to the default value set in parameter P2-05

85

Number Hold

Holds the last value input until de-activated

86

CASE DI 7

Reserved

Terminal 3 Sel
Terminal 4 Sel
Terminal 5 Sel
Terminal 6 Sel
Terminal 7 Sel
Terminal 8 Sel

H1-01
H1-02
H1-03
H1-04
H1-05
H1-06

87

CASE DI 8

Reserved



3.4

Function H2 Digital Outputs

Display Constant

Setting

Display Description

40

CONNECTION 80

Switch function with a common output to a NO and NC input

41

CONNECTION 81

Switch function with a common output to a NO and NC input

Terminal 9 Sel
Terminal 25 Sel
Terminal 26 Sel

H2-01
H2-02
H2-03

42

CONNECTION 82

Increases the MOP value



3.5

Function H4 Analog Outputs

Display Constant

Setting

Display Description

50

Case Monitor 1

Links the value in U1-50 to the selected analog output

Terminal 21 Sel
Terminal 23 Sel

H4-01
H4-04

51

Case Monitor 2

Links the value in U1-51 to the selected analog output



3.6

Group F Options

Constant F1-01, Pulses Per Rev is enabled in all control methods