Table 1-2. Terminal Functions and Voltages

Tightening

Wire

Model

Terminal Symbol

Screw

Torque

Applicable size

Recommended

lb • in (N • m)

size

Type

mm

2

AWG

mm

2

AWG

MA, MB, MC

M3

4.44 to 5.33

twisted wire 0.5 to 1.25 20 to 16

0.75

18

Common

(0.5 to 0.6)

single

0.5 to 1.25 20 to 16

Shielded

to

S1 to S7, P1, P2, SC,

1.94 to 2.21

twisted wire 0.5 to 0.75 20 to 18

wire or

all models

PC, R+, R-, S+, S-,

M2

(0.22 to 0.25) single

0.5 to 1.25 20 to 16

0.75

18

equivalent

FS, FR, FC, AM, AC, RP

TERMINAL

FUNCTION

VOLTAGE / SIGNAL LEVEL

L1 (R)

230V Drive: 200 / 208 / 220 / 230V at 50/60 Hz

L2 (S)

Main circuit input power supply

460V Drive: 380 / 400 / 440 / 460 / 480V

L3 (T)

at 50/60 Hz

T1 (U)
T2 (V)

Main circuit output

230V Drive: 0 - 200 / 208 / 220 / 230V

T3 (W)

460V Drive: 0 - 400 / 440 / 460 / 480V

B1

For connection of braking resistor (option)

B2

+1

DC Reactor terminals

+2

DC Bus terminals (+1 & –)

Ground terminal (100 ohms or less)

– – – –

S1

Multi-Function-Input 1

Factory setting is " Forward Run/Stop " (1).

(Forward run when closed, stop when open)

S2

Multi-Function-Input 2

Factory setting is " Reverse Run/Stop " (1).

(Reverse Run when closed, stop when open)

S3

Multi-Function-Input 3

Factory setting is " External Fault (NO contact)

input " (1)

S4

Multi-Function-Input 4

Factory setting is " Fault Reset " (1)

Control Circuit

Table 1-1. Wire and Terminal Screw Sizes - continued