Drive parameter listing (n070-n079), Drive parameters - continued – Yaskawa V74X Drives User Manual
Page 42

Drive Parameter Listing
(n070-n079)
Section 8
PARA-
SETTING RANGE
SETTING
FACTORY
USER
PARA.
METER
NAME
(AND UNITS)
INCREMENT
SETTING
SETTING
REF.
Analog Frequency Reference
n070
Filter Time Constant
0.00 to 2.00
0.01 s
0.10
(CN2, Voltage Ref Input)
n071
Analog Frequency Reference
-255 to 255
1%
100
Gain (CN2, Current Ref Input)
n072
Analog Frequency Reference
-100 to 100
1%
0
5.32
Bias (CN2, Current Ref Input)
Analog Frequency Reference
n073
Filter Time Constant
0.00 to 2.00
0.01 s
0.10
(CN2, Current Ref Input)
n074
Pulse Train Frequency
-255 to 255
1%
100
Reference Gain
n075
Pulse Train Frequency
-100 to 100
1%
0
5.11
Reference Bias
n076
Pulse Train Frequency Ref-
0.00 to 2.00
0.01 s
0.10
erence Filter Time Constant
0:
Multi-Function analog input disabled
1:
Aux. Frequency reference
n077
Multi-Function Analog
2:
Frequency gain
0
1
Input Selection
3:
Frequency bias
4:
Voltage bias
n078
Multi-Function Analog Input
0:
0 - 10V
1
0
5.32
Signal Selection
1:
4 - 20 mA
n079
Multi-Function Analog Input
0 to 50
1%
10
Bias Setting
Drive Parameters - Continued
42