Yaskawa GPD 515/G5 to F7 User Manual

Page 33

Advertising
background image

Product Transition Guide

Appendix 2- Parameter Differences

____________________________

PL.F7.02.TransitionGuide 6/5/06

Page 33 of 40

Yaskawa Electric America, Inc

GPD515/G5 Parameters

F7 Parameters

Parameter

No.

Name

(DigitalOperator

Display)

Setting or Selection

Parameter

No.

Name

(Digital Operator Display)

Remarks on

Setting or Selection

H2-01

Multi-function Input
Terminal 9-10

H2-01

Terminal M1-M2
Function Selection

Additional selections:
32: During Speed Limit
38: Drive Enable

H2-02

Multi-function Input
Terminal 25

H2-02

Terminal M3-M4
Function
Selection

Terminal number renamed

H2-03

Multi-function Input
Terminal 26

H2-03

Terminal M5-M6
Function Selection

Terminal number renamed

H3-01

Signal Level
Selection Terminal
13

H3-01

Terminal A1 Signal
Level Selection

Terminal number renamed

H3-02

Terminal 13 Gain

Frequency reference gain of AI-14U, AI-14B 3ch
addition input, DI-08, and DI-16 is common.

H3-02

Terminal A1 Gain
Setting

Terminal number renamed

H3-03

Terminal 13 Bias

H3-03

Terminal A1 Bias
Setting

Terminal number renamed

H3-04

Terminal 16 Signal
Level Selection

0:0 - 10 VDC
1:10 +10 VDC

H3-04

Terminal A3 Signal
Level Selection

Terminal number renamed

H3-05

Terminal 16
Multifunction
Analog Input

Multi-function analog input selection terminal 16
0: Auxiliary Reference
1: Frequency Gain
2: Frequency Bias
4: Voltage Bias
5: Accel/Decel Change
6: DC Brake Current
7: Overtorque Level
8: Stall Prevention Level
9: Reference Lower Limit
A: Jump Frequency
B: PID Feedback
C: PID Setpoint
D: Frequency Bias 2
10: Forward Torque Limit
11: Reverse Torque Limit
12: Regenerative Torque Limit
13: Torque reference
14: Torque Compensation
15: Forward/Reverse Torque Limit
1F: Not Used

Modified selection:
2:Aux Frequency Reference1
Used in conjunction with
multi-function inputs “multi-
step frequency reference 1-4”.

Additional
3:Aux Frequency Reference 2
Used in conjunction with
multi-function inputs “multi-
step frequency reference 1-4”.
E: Motor Temperature
See parameters L1-03 &
L1-04.

H3-06

Terminal 16 Gain

H3-06

Terminal A3 Gain
Setting

Terminal number renamed

H3-07

Terminal 16 Bias

H3-07

Terminal A3 Bias
Setting

Terminal number renamed

H3-08

Signal Level
Selection Terminal
14

H3-08

Terminal A2 Signal
Level
Selection

Terminal number renamed

H3-09

Multi-function
Analog Input
Terminal 14

H3-09

Terminal A2 Function
Selection

Terminal number renamed

H3-10

Terminal 14 Gain

H3-10

Terminal A2 Gain
Setting

Terminal number renamed

H3-11

Terminal 14 Bias

H3-11

Terminal A2 Bias
Setting

Terminal number renamed










Advertising