Yaskawa GPD 515/G5 to F7 User Manual
Page 7

Product Transition Guide
GPD515/G5 to F7 Feature Differences
__________________________
PL.F7.02.TransitionGuide 6/5/06
Page 7 of 40
Yaskawa Electric America, Inc
Feature
Item
Yaskawa GPD515/G5
Yaskawa F7
- Filters/Reactors
(Options)
12 Pulse: 30HP and Above
Filters/Reactors (Options)
Harmonic Counter
Measures
Built-In DC Bus
Reactor
230Vac: 18.5-75kW
460Vac: 18.5-160kW
240Vac: 22-110kW
480Vac: 22-300kW
Ambient Temperature
ºC
-10ºC ~ +40ºC (IP21)
-10ºC ~ +45ºC (IP00)
-10ºC ~ +40ºC (IP21)
-10ºC ~ +45ºC (IP00)
(Automatic OL protection curve
based on ambient temperature setting
of L8-12)
Storage Temperature
ºC
-10ºC ~ +60ºC
-20ºC ~ +60ºC
Standard
Modbus RTU via RS232
Modbus RTU
via terminal I/O RS485/422
Network Communications
Optional
RS232 to RS485, DeviceNet,
ProfibusDP, Interbus-S, Lonworks,
ModbusPlus, CanOpen,CC-link
DeviceNet, Profibus-DP, Interbus-S,
ControlNet, Ethernet, CC Link,
CanOpen
Unique Feature / Function
-
HSB – High Slip Braking
Split front cover
-
No
Yes
Modular heat sink fan
-
No
Yes
I/O Terminal Arrangement
-
Numerically labeled
Alpha Numeric labels
Mounting Conversion Kit
Yes (G3 to GPD515/G5)
No