PL.F7.02.TransitionGuide 6/5/06

Page 39 of 40

Yaskawa Electric America, Inc

GPD515/G5 Parameters

F7 Parameters

Parameter

No.

Name

(DigitalOperator

Display)

Setting or Selection

Parameter

No.

Name

(Digital Operator Display)

Remarks on

Setting or Selection


o2-14

kWh User Monitor
Initialization

New parameter
0: Disabled no change.
1: Enabled - Resets U1-29 to
zero and returns o2-14 to zero.














o3-01

Copy Function
Selection

New parameter
0: COPY SELECT no
function
1: INV -> OP READ - All
parameters are copied from
the Drive to the digital
operator.
2: OP -> INV WRITE - All
parameters are copied from
the digital operator to the
Drive.
3: OP<-->INV VERIFY -
Parameter settings in the
Drive are compared to those
in the digital operator.
NOTE: When using the copy
function, the Drive model
number o2-04, software
number U1-14, and control
method A1-02 must match or
an error will occur.

o3-02

Copy Allowed
Selection
Read Allowable

New parameter
0: Disabled - No digital
operator copy functions are
allowed.
1: Enabled - Copying allowed

Advertising